TWINLINK® High temperature twisted pair controlled impedance

TWINLINK® High temperature twisted pair controlled impedance

Discover our new range TWINLINK® of twisted pair controlled impedance. These cables have been specially developed for data transmission with impedance matching.

  • TWINLINK® FP = High temperature +200°C and small size twisted pair
  • TWINLINK® FA = High temperature +260°C and small size twisted pair

For each products, the impedance 50Ω, 75Ω, 100Ω, 120Ω are available in AWG22, AWG24, AWG26.

For high temperature twisted pair, we propose on study reduced size versions with foamed insulation.

You can download all our specifications sheets form the links below

Home page > Applications du groupe > CGP > TWINLINK® High temperature twisted pair controlled impedance

TWINLINK® High temperature twisted pair controlled impedance

TWINLINK® FP 120 / 100 / 75 / 50 Ohms

TWINLINK® FP 120 / 100 / 75 / 50 Ohms

Application : data transmission
Composition : pair
Core : silver plated copper, flexible
Insulation or sheath : fluorinated FEP
Shield / armour : shielded
Temperature : -55°C to +200°C
Voltage rating : 600 V
Impedance (4 models) : 120 / 100 / 75 / 50 Ohms
Available range  : AWG 22, 24, 26

TWINLINK® FA 120 / 100 / 75 / 50 Ohms

TWINLINK® FA 120 / 100 / 75 / 50 Ohms

Application : data transmission
Composition : pair
Core : silver plated copper, flexible
Insulation or sheath : fluorinated PFA
Shield / armour : shielded
Temperature : -90°C to +260°C
Voltage rating : 600 V
Impedance (4 models) : 120 / 100 / 75 / 50 Ohms
Available range  : AWG 22, 24, 26